Application of radar liquid level in corrosive liquid

Huachuang measurement and control Huachuang measurement and Control Technology Co., Ltd 2023-08-04 15:14

Chemical storage tanks in chemical plants store sulfuric acid, hydrochloric acid, hydrofluoric acid, sodium hydroxide, thick alkali and other corrosive media. In the encounter, these corrosive media are recommended to use the 26G anticorrosive radar liquid level meter, and use non -contact radar liquid levels to measure sulfuric acid, hydrochloric acid, nitric acid and other corrosive liquids. We need to consider three aspects when selecting the liquid level.

1691133026898509.jpg

First, the principle of non -contact measurement needs to be considered. The probe of the 26G non -contact radar liquid level of Huacchuang measurement and control does not require contact medium. The principle of induction band is used to obtain the current liquid level information. When the radar liquid level meter is measured, the material selected by the probe is fourfluoro. At the same time, it is a full -closed anti -corrosion structure, so it is measured with a thick, corrosive, turbid liquid, and the effect is excellent.

Second, it is necessary to consider the convenience of on -site installation. Due to the uniqueness of corrosive liquid measurement such as sulfuric acid, hydrochloric acid, and nitrate, it is necessary to simply install it on the spot and simply open the jar.

The level of 26G anti -corrosion radar liquid of Huachuang measurement and control has the characteristics of reliable work, easy installation, long use cycle, and maintenance.

1691133207810839.jpg

The third is the choice of the host part. As the host part, the seal is required. As long as the medium is leaked, it is possible to enter the interior of the liquid level from the shell or the network inlet, causing the internal circuit board to be corroded. Therefore, it is recommended to use the 26G anti -corrosion high -frequency radar liquid level of Huaisuang measurement and control to protect the service life of the host.

If concentrated sulfuric acid and hydrochloric acid exceeds a certain temperature range, the phenomenon of steam or vaporization is generated, and it is necessary to consider the actual situation at the scene and re -select the appropriate liquid level meter.

If you have a need, please contact us!

Contact number: 400-851-0898